Meter Star Universal LPG Propane Fireplace Fire Pit Gas Control Cock Valve Kit with Thermocouple and Knob Switch, Replacement for Gas Grill,Heater,Fire Pit,Fireplace(3/8" Flare Inlet & Outlet)

Meter Star Universal LPG Propane Fireplace Fire Pit Gas Control Cock Valve Kit with Thermocouple and Knob Switch, Replacement for Gas Grill,Heater,Fire Pit,Fireplace(3/8" Flare Inlet & Outlet)

货号 AMA-FM009-RDO003-XN003A 产品编码 757818045739
  • Low Working Pressure Max 1/2 PSI(65mbar), CE&CSA tested Main Control Valve In & Out with 5/8"-18UNEF Male Flare thread
  • Highlights
  • Length of Thermocoupler 600mm Head Tip M8*1
  • Platic Black Bakelite Knob Diameter 64mm and "D" Insert for Valve 9.0-9.1mm
  • Suitable for Low Pressure Repair Control System for Grill, Fire Pit, Fireplace & Heater (max BTU rating: 50000 working pressure 65mbar)

产品详情

Highlights - Low Working Pressure Max 1/2 PSI(65mbar), CE&CSA tested Main Control Valve In & Out with 5/8"-18UNEF Male Flare thread - Length of Thermocoupler 600mm Head Tip M8*1 - Platic Black Bakelite Knob Diameter 64mm and "D" Insert for Valve 9.0-9.1mm - Suitable for Low Pressure Repair Control System for Grill, Fire Pit, Fireplace & Heater (max BTU rating: 50000 working pressure 65mbar) - Keep The Thermocoupler to be Heated and Push the Valve around 5-10s Then Release Hand (if Flame stops, Ajust the location of Thermocouple tip) The valve is a low pressure valve with 5/8"-18UNEF Male flare thread on Entrance & Exit
Operation Instructions
1). Fix the valve on a plate or board of your grill or fire pit by the head screw and flange.
2). Connect your inlet and outlet hose on inlet and outlet side. (faston it tightly enough in case of gas leakage)
3). Faston the thermocouple nut M8 on the valve end tightly (Check if your valve end thread if 8mm before you buy)
4). Connect thermocouple and end thread well
5). Open gas by correct size knob and push your valve around 5-10s till the thermocouple head is heated enough.
6). Release your hand and it work properly If when you release hand, gas valve shut off again, Please check
a. If your thermocouple is always be heated on flame
b. If the thermocouple end is well connect with valve
c. If the inlet and outlet side well connect with hose you have
Possible problems occurs during your use:
1) Valve after turn can not stick during using
reason: a. The thermocouple head is not heated in right place, please adjust thermocouple tip position.
b. The connection between thermocouple end and valve is not connected tight enough or too tight, please adjust the screw again
c. Need to push valve first then turn the spindle and hold for few seconds, it cannot stick immediately may need 10-30Seconds

常见问题

如何确认兼容性?

请对比产品页面上显示的商品编号、产品图片、尺寸、变体选项和型号信息。如果该零件用于燃气、加热、电气或安全相关设备,请在下单前联系我们。

你们支持批量采购吗?

欢迎小批量批发咨询。请发送商品编号、数量、目的地国家以及任何包装或配送要求,我们将审核库存并提供实际报价。